Motor Valve

Please refer to the model to be equipped with valves.
PHOTO
MODEL
The Size of valve
 
MAX.
OPERATING
PRESSURE
DIFF.
KGF/CM 2
Screwed
Ends
Flanged
Ends
True union
Ball valve
Butterfly
3-Way
Valve
球型閥閘閥閘刀閥
UM-1
1/2" ~ 11/2"
1/2" ~ 1
1/2"~11/2"
 
1/2"~1"
 
10
UM-2
1/2"~2"
1/2"~2"
1/2"~2"
2"~ 3"
11/4"~11/2"
 
10
UM-3
11/4"~3"
11/4"~3"
11/4"~3"
2"~ 4"
2"
 
10
UM-3-1
11/4"~3"
11/4"~3"
11/4"~3"
2"~ 5"
2"
 
10
UM-4
 
4"
 
5"~ 8"
21/2"~3"
 
10
UM-5
 
5"
 
10"
4"
 
10
UM-6
 
6"
 
12"
 
 
10
UM-8
 
8"
0
14"
0
0
10
UM-100
10"
0
14"~16"
0
0
10
UM-110
12"
0
18"
00
10
UM-120
14"
0
20"~24"
0
0
10
UMA-1
1/2" ~ 11/2"
0
0
0
0
0
10
UMA-2
1/2" ~ 2"
0
0
2"~3"
0
0
10
UMB
00000
2"~4"
10
UMD
1/2" ~ 3"1/2" ~ 14"1/2" ~ 4"2" ~ 24"1/2" ~ 2"
2" ~ 6"
10
If the pressure applied exceeds 10kgf/cm 2 ,then the electrical head in one inch more shall be
required.

Standard and features:
1.The UM series' electric head adopts a powerful motor with low power consumption and high-efficiency and excellent weather endurance.
2.The casing of the product adopts a "Nylon" material with features including high temperature, acid and alkali resistance, while the main bodies UM3~UM12 are formed by using aluminum alloy.
3. Provided with waterproof seals on all the joints on the body's casing, so it is applicable to uses in outdoors environment.
4. The speed after startup is stable so that the water hammer phenomenon can be effectively avoided in order to increase the use life of the pipework.
5. All the UM-1 and UM-2 electric valves series can be examined from the outside for a valve's switch (O-OPEN/S-CLOSE) position, or can be indicated by the wiring for the position if a control box is installed.
6.All the UM-3~UM-12 series can be examined from the top window for a valve's switch (O-OPEN/S-CLOSE) position, or can be indicated by the wiring for the position if a control box is installed.
7. At the bottom of the UM-1-UM-3 is provided with a manual device which can be used to perform the switching movement through the manual shaft (an 8mm wrench) during power outage.
8. On the side of the UM-3-1~UM-12 is provided with a manual device which can be used to perform the switching movement through the manual wheel during power outage.
9. If the fluid applied is above 150℃, it should be custom-made otherwise.
10.The proportional circuit board can be installed through UM-1~-UM-12
11.11. Water proofing level: IP67.